- Frekvens, period, pulslängd, frekvensförhållande, arbetscykel och händelseräknarlägen
- DC till 3000 eller 6000MHz område, 0.001mHz upplösning
- Hög impedansmätning upp till 125 MHz
- AC eller DC koppling, 1M/50Ohm val, polaritetsinversion
- Bytbar dämpare, tröskelkontroll
- Brusfilter för lågfrekvensmätningar
- Valbar mättid; displayhållfunktion
- Stor 10-siffrig display med fullt utbud av indikatorer
- Inbyggda uppladdningsbara batterier för portabel användning
- USB-gränssnitt ger full fjärrkontroll och avläsning
Upptäck möjligheterna
Mer information
Beskrivning
Aim-TTi TF960 Universal Counter
High measurement accuracy
The Aim-TTi TF960 use a high quality temperature compensated internal frequency reference (TCXO) which has a low aging rate and is stable to within ±1ppm over the full temperature range. Its short warm-up time allows accurate measurements to be made even under portable battery powered conditions. An External Reference input is provided and changeover from the internal timebase is automatic when an external reference standard is connected.High resolution
For frequency, period and frequency ratio functions the instrument uses a reciprocal counting technique to provide high resolution at all frequencies. Eight significant digits of answer are produced in a 1 second measurement time, nine digits in 10s and ten digits in 100s with a granularity of less than 2 counts in the least significant digit.Flexible signal conditioning
Input A has configurable coupling (AC or DC), input impedance (1MW or 50W), attenuation (1:1 or 5:1), threshold (fully variable) and active edge, and can be used for frequencies in the range 0.001Hz to >125MHz. Input B is a nominal 50W input for frequencies in the range 80MHz to > 3GHz. Input C (TF960 only) uses a standard N connector and has a nominal 50W input for frequencies in the range 1.8GHz to > 6GHz.Multiple measurement functions
The Aim-TTi TF960 can measure frequency, period, pulse width, duty cycle and frequency ratio, as well as event counting (totalise).Remote control and read-back via USB
The Aim-TTi TF960 incporporate a USB interface which allows it to be remotely controlled using RS232 protocol via a computer’s USB port. The remote commands of their predecessor instrument, the TF830, are compatible with the command set.Battery operation when needed
The Aim-TTi TF960 operate from internal rechargeable NiMH batteries which give typically 24 hours operating life. The universal AC charger supplied will recharge the batteries in less than 4 hours and can be used for continuous AC operation. The instruments can also be powered from a standard USB port.
Ten digit LCD
The high contrast display has ten 12.5mm (0.5”) high digits along with a comprehensive set of annunciators. These show input configuration and function, measurement time and status, external reference connection, low battery and the units of the measurement which may be Hz, kHz, MHz, ns, us, ms or s.For more information: Aim-TTi
Dokument
Aim-TTi TF960 Universal Counter
AIM-TTi TF900 series DatasheetAlternativ
Video
Aim-TTi TF960 Universal Counter
High measurement accuracy
The Aim-TTi TF960 use a high quality temperature compensated internal frequency reference (TCXO) which has a low aging rate and is stable to within ±1ppm over the full temperature range. Its short warm-up time allows accurate measurements to be made even under portable battery powered conditions. An External Reference input is provided and changeover from the internal timebase is automatic when an external reference standard is connected.High resolution
For frequency, period and frequency ratio functions the instrument uses a reciprocal counting technique to provide high resolution at all frequencies. Eight significant digits of answer are produced in a 1 second measurement time, nine digits in 10s and ten digits in 100s with a granularity of less than 2 counts in the least significant digit.Flexible signal conditioning
Input A has configurable coupling (AC or DC), input impedance (1MW or 50W), attenuation (1:1 or 5:1), threshold (fully variable) and active edge, and can be used for frequencies in the range 0.001Hz to >125MHz. Input B is a nominal 50W input for frequencies in the range 80MHz to > 3GHz. Input C (TF960 only) uses a standard N connector and has a nominal 50W input for frequencies in the range 1.8GHz to > 6GHz.Multiple measurement functions
The Aim-TTi TF960 can measure frequency, period, pulse width, duty cycle and frequency ratio, as well as event counting (totalise).Remote control and read-back via USB
The Aim-TTi TF960 incporporate a USB interface which allows it to be remotely controlled using RS232 protocol via a computer’s USB port. The remote commands of their predecessor instrument, the TF830, are compatible with the command set.Battery operation when needed
The Aim-TTi TF960 operate from internal rechargeable NiMH batteries which give typically 24 hours operating life. The universal AC charger supplied will recharge the batteries in less than 4 hours and can be used for continuous AC operation. The instruments can also be powered from a standard USB port.
Ten digit LCD
The high contrast display has ten 12.5mm (0.5”) high digits along with a comprehensive set of annunciators. These show input configuration and function, measurement time and status, external reference connection, low battery and the units of the measurement which may be Hz, kHz, MHz, ns, us, ms or s.For more information: Aim-TTi